Customization: | Available |
---|---|
After-sales Service: | 24 Hours |
Warranty: | One Year |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Measuring parameters | |||
Measuring range | Accuracy | Resolution | |
Ultrasonic wind speed | 0~70m/s | Start wind ≤0.8m/s, ±(0.5+0.02V)m/s |
0.01m/s |
Ultrasonic wind direction | 0~360° | ±3° | 1° |
Air temperature | -40~100°C | ±0.3°C | 0.1°C |
Air humidity | 0~100%RH | ±5%RH | 0.1%RH |
Air pressure | 300~1100hPa | ±1 hPa(25°C) | 0.1 hPa |
Rainfall (Drop sensing rainfall) | 0~4mm/min | ±4% | 0.03mm |
Illuminance | 0~200000 Lux (Outdoor) | ±4% | 1 Lux |
Radiation | 0~1500 W/m2 | ±5% | 1W/m2 |
CO2 | 0~5000ppm | ±(50ppm+5%) | 1ppm |
Noise | 30~130dB(A) | ±3dB(A) | 0.1 dB(A) |
PM2.5/10 | 0~500μg/m3 | ≤100ug/m3: ±10ug/m3; >100ug/m3: ±10% of reading (calibrated with TSI 8530, 25±2°C, 50±10%RH ambient conditions) |
1μg/m3 |
PM100 | 0~20000μg/m3 | ±30μg/m3±20% | 1μg/m3 |
CO | 0~1000ppm | ≤±3% of reading (25°C) | 0.1ppm |
NO2 | 0~20ppm | ≤±3% of reading (25°C) | 0.01ppm |
SO2 | 0~20ppm | ≤±3% of reading (25°C) | 0.01ppm |
O3 | 0~10ppm | ≤±3% of reading (25°C) | 0.01ppm |
Compass | 0~360 | ±5° | 1° |
Longitude | -180~180° | ≤10m | 0.1s |
Latitude | -90~90° | ≤10m | 0.1s |
Altitude | -3276.7~3276.7m | ≤3m | 0.1m |
Electrical parameter | |||
Power supply | DC9 ~30V or DC5V | ||
Power consumption | 0.4W (10.5W when heating) | ||
Output | RS485 Modbus-RTU(Default). 4~20mA/0~5V(only for ultrasonic anemometer--with External transmitter) |
||
Working temperature | -40°C~+60°C | ||
Working humidity | 0~100%RH | ||
Mechanical structure parameter | |||
Material | ABS engineering plastic | ||
Entry cable | Aviation socket, sensor cable 3 meters | ||
Color | White | ||
Ingress Protection | IP65 |