Customization: | Available |
---|---|
After-sales Service: | 1 Year |
Warranty: | 1 Year |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Items
|
Performance &Parameter
|
|
|
Convertor
|
Principle
|
Transit-time ultrasonic flowmeter
|
|
|
Accuracy
|
±1%
|
|
|
Display
|
2x20 character LCD with backlight, support the language of Chinese, English, Italy, Turkish
|
|
|
Signal Output
|
1way 4-20mA output, electric resistance 0-1K, accuracy0.1%
|
|
|
|
1 way OCT pulse output(Pulse width-1000ms, default is 200ms))
|
|
|
|
1 way Relay output
|
|
|
Signal Input
|
3 way 4-20mA input, accuracy 0.1%, acquisition signal such as temperature, press and liquid level
|
|
|
|
Connect the temperature transducer P100, can finish the heat/energy measurement.
|
|
|
Data Interface
|
Insulate Rs485 serial interface, upgrade the flowmeter software by computer, support the MODBUS.
|
|
Special Cable
|
|
Twisted-pair cable, generally, the length under 50 meters, select the Rs485, transmission distance can over 1000m
|
|
Pipe Installation Condition
|
Pipe material
|
Steel, stainless steel, cast iron, copper, cement pipe, PVC, Aluminum, glass steel product, liner is allowed
|
|
|
Pipe diameter
|
|
|
|
Straight pipe
|
Transducer installation should be satisfied: upstream10D, downstream5D, 30D from the pump.
|
|
Measuring Medium
|
Type of liquid
|
Single liquid can transmit sound wave; such as water (hot water ,chilled water, city water, sea water, waste water, etc); sewage
with small particle con tent, oil(curde oil, lubricating oil, diesel oil, fuel oil, etc); chemicals(alcohol, etc); plant effluent; beverage; Ultra-pure liquids, etc |
|
|
Temperature
|
-30-160
|
|
|
Turbidity
|
No more than 10000ppm and less bubble
|
|
|
Flow rate
|
0-±7m/s
|
|
Working
|
Temperature
|
Convertor; -20-60; Flow Transducer: -30-160
|
|
Environment
|
Humidity
|
Convertor: 855RH; Flow Transducer: can measure under water, water depth≤2m
|
|
Power Supply
|
|
DC8-36V or AC85-264V(Optional)
|
|
Power Consumption
|
|
1.5W
|
|
Dimension
|
|
132*150*85mm(convertor)
|