Customization: | Available |
---|---|
After-sales Service: | 24 Hours |
Warranty: | One Year |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Items | Performance &Parameter | |
Convertor | Principle | Transit-time ultrasonic flowmeter |
Accuracy | ±1% | |
Display | 2x20 character LCD with backlight, support the language of Chinese, English, Italy, Turkish | |
Signal Output | 1way 4-20mA output, electric resistance 0-1K, accuracy0.1% | |
1 way OCT pulse output(Pulse width-1000ms, default is 200ms)) | ||
1 way Relay output | ||
Signal Input | 3 way 4-20mA input, accuracy 0.1%, acquisition signal such as temperature, press and liquid level | |
Connect the temperature transducer P100, can finish the heat/energy measurement. | ||
Data Interface | Insulate Rs485 serial interface, upgrade the flowmeter software by computer, support the MODBUS. | |
Special Cable | Twisted-pair cable, generally, the length under 50 meters, select the Rs485, transmission distance can over 1000m | |
Pipe Installation Condition | Pipe material | Steel, stainless steel, cast iron, copper, cement pipe, PVC, Aluminum, glass steel product, liner is allowed |
Pipe diameter | ||
Straight pipe | Transducer installation should be satisfied: upstream10D, downstream5D, 30D from the pump. | |
Measuring Medium | Type of liquid | Single liquid can transmit sound wave; such as water (hot water ,chilled water, city water, sea water, waste water, etc); sewage with small particle con tent, oil(curde oil, lubricating oil, diesel oil, fuel oil, etc); chemicals(alcohol, etc); plant effluent; beverage; Ultra-pure liquids, etc |
Temperature | -30-160℃ | |
Turbidity | No more than 10000ppm and less bubble | |
Flow rate | 0-±7m/s | |
Working | Temperature | Convertor; -20-60℃; Flow Transducer: -30-160℃ |
Environment | Humidity | Convertor: 855RH; Flow Transducer: can measure under water, water depth≤2m |